
Furnace
- Air Pressure Switches
- Blower Motors
- Blower Wheels
- Burners
- Capacitors
- Condensate Traps
- Control Circuit Boards
- Door Switches
- Duct & Accessories
- Flame Sensors
- Furnaces
- Gas Valves
- Heating Elements
- Ignitors
- Limit Switches
- Motors Inducer \ Exhaust
- Oil Nozzles
- Pilot Assemblies \ Orifices
- Relays
- Thermostats
- Transformers
- Wiring Harnesses
-
ClimaTek Flame Sensor Replaces York Luxaire Coleman S1-02527773000 025-27773-000
Fits York Luxaire Coleman
$6.99This is a new ClimaTek Flame Sensor It replaces the part numbers listed below.Function:A flame sensor senses the furnace flame ensuring that ignition has occurred. It then monitors the flame until the furnace shut down. Should combustion be disrupted for...$6.99 -
ClimaTek Flame Sensor Rod Replaces York Luxaire Coleman PSE-Y37
Fits York Luxaire Coleman
$9.99This is a new ClimaTek Flame Sensor Rod It replaces the part numbers listed below.Function:A flame sensor senses the furnace flame ensuring that ignition has occurred. It then monitors the flame until the furnace shut down. Should combustion be disrupted...$9.99 -
ClimaTek Flame Sensor Rod Fits York Luxaire Coleman S1-02537499000 025-37499-000
Fits York Luxaire Coleman
$6.99This is a new ClimaTek Flame Sensor Rod It replaces the part numbers listed below.Function:A flame sensor senses the furnace flame ensuring that ignition has occurred. It then monitors the flame until the furnace shut down. Should combustion be disrupted...$6.99 -
ClimaTek Furnace Flame Sensor Rod Replaces York Luxaire Coleman 17613 PSE-E11
Fits York Luxaire Coleman
$21.99This is a new ClimaTek Furnace Flame Sensor Rod It replaces the part numbers listed below.Function:A flame sensor senses the furnace flame ensuring that ignition has occurred. It then monitors the flame until the furnace shut down. Should combustion be...$21.99 -
ClimaTek Flame Sensor Rod Fits York Luxaire Coleman S1-02535354000 025-35354-000
Fits York Luxaire Coleman
$21.99This is a new ClimaTek Flame Sensor Rod It replaces the part numbers listed below.Function:A flame sensor senses the furnace flame ensuring that ignition has occurred. It then monitors the flame until the furnace shut down. Should combustion be disrupted...$21.99 -
ClimaTek Flame Sensor Rod Fits York Luxaire Coleman S1-02530788000 025-30788-000
Fits York Luxaire Coleman
$13.99This is a new ClimaTek Flame Sensor Rod It replaces the part numbers listed below.Function:A flame sensor senses the furnace flame ensuring that ignition has occurred. It then monitors the flame until the furnace shut down. Should combustion be disrupted...$13.99 -
ClimaTek Flame Sensor Rod Fits York Luxaire Coleman S1-02530788700 025-30788-700
Fits York Luxaire Coleman
$13.99This is a new ClimaTek Flame Sensor Rod It replaces the part numbers listed below.Function:A flame sensor senses the furnace flame ensuring that ignition has occurred. It then monitors the flame until the furnace shut down. Should combustion be disrupted...$13.99 -
OEM York Luxaire Coleman Condenser Fan Motor 1/3 HP 682 RPM Fits S1-32440880007
Fits York Luxaire Coleman
$418.99This is a brand new OEM York Luxaire Coleman upgraded Condenser Fan Motor 1/3 HP 682 RPM. It replaces the part numbers listed below.Function:An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn...$418.99 -
OEM York Luxaire Coleman Furnace Blower Motor 1/4 HP CCW Replaces S1-02440878000
Fits York Luxaire Coleman
$220.99This is a brand new OEM York Luxaire Coleman upgraded Furnace Blower Motor 1/4 HP CCW. It replaces the part numbers listed below.Function:An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn the...$220.99 -
OEM York Luxaire Coleman Condenser Fan Motor 1/4 HP 850 RPM Fits S1-02440892000
Fits York Luxaire Coleman
$238.99This is a brand new OEM York Luxaire Coleman upgraded Condenser Fan Motor 1/4 HP 850 RPM. It replaces the part numbers listed below.Function:An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn...$238.99 -
ClimaTek Furnace Blower Motor Replaces York Luxaire Coleman FHM3587 S1-FHM3587
Fits York Luxaire Coleman
$146.99This is a new ClimaTek Furnace Blower Motor The Motor is 1/2 HP, 115 voltage, and 1075 RPM. It replaces the part numbers listed below.Function:An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn...$146.99 -
ClimaTek Furnace Blower Motor Replaces York Luxaire Coleman B0603161 S1-B0603161
Fits York Luxaire Coleman
$146.99This is a new ClimaTek Furnace Blower Motor The Motor is 1/2 HP, 115 voltage, and 1075 RPM. It replaces the part numbers listed below.Function:An electric motor converts electrical energy into mechanical energy. In an HVAC system, motors typically turn...$146.99